Applying a DCB Map on a Port
When you apply a DCB map with PFC enabled on a switch interface, a memory buffer for PFC-enabled
priority traffic is automatically allocated. The buffer size is allocated according to the number of PFC-
enabled priorities in the assigned map.
To apply a DCB map to an Ethernet port, follow these steps:
Step Task Command Command Mode
1
Enter interface configuration mode on an
Ethernet port.
interface
{tengigabitEthernet slot/
port |
fortygigabitEthernet
slot/port}
CONFIGURATION
2
Apply the DCB map on the Ethernet port to
configure it with the PFC and ETS settings in
the map; for example:
Dell# interface tengigabitEthernet 1/1
Dell(config-if-te-1/1)# dcb-map
SAN_A_dcb_map1 Repeat Steps 1 and 2 to
apply a DCB map to more than one port.
You cannot apply a DCB map on an interface
that has been already configured for PFC using
thepfc priority command or which is
already configured for lossless queues (pfc
no-drop queues
command).
dcb-map name
INTERFACE
Configuring PFC without a DCB Map
In a network topology that uses the default ETS bandwidth allocation (assigns equal bandwidth to each
priority), you can also enable PFC for specific dot1p-priorities on individual interfaces without using a
DCB map. This type of DCB configuration is useful on interfaces that require PFC for lossless traffic, but
do not transmit converged Ethernet traffic.
Step Task Command Command Mode
1 Enter interface configuration mode on an
Ethernet port.
interface
{tengigabitEthernet slot/
port |
fortygigabitEthernet
slot/port}
CONFIGURATION
2 Enable PFC on specified priorities. Range:
0-7. Default: None.
pfc priority
priority-range
INTERFACE