Example of Viewing a Monitoring Session
In the example below, 0/25 and 0/26 belong to Port-pipe 1. This port-pipe has the same restriction of
only four destination ports, new or used.
Dell(conf-mon-sess-300)#do show mon session
SessionID Source Destination Direction Mode Type
--------- ------ ----------- --------- ---- ----
0 Te 1/13 Te 1/1 rx interface Port-based
10 Te 1/14 Te 1/2 rx interface Port-based
20 Te 1/15 Te 1/3 rx interface Port-based
30 Te 1/16 Te 1/37 rx interface Port-based
100 Te 1/25 Te 1/38 tx interface Port-based
110 Te 1/26 Te 1/39 tx interface Port-based
300 Te 1/17 Te 1/1 tx interface Port-based
Dell(conf-mon-sess-300)#
Given these parameters, the following illustration shows the possible port monitoring configurations on
the S-Series.
Figure 99. Port Monitoring Configurations on the S-Series
Dell Networking OS Behavior: All monitored frames are tagged if the configured monitoring direction is
egress (TX), regardless of whether the monitored port (MD) is a Layer 2 or Layer 3 port. If the MD port is a
Layer 2 port, the frames are tagged with the VLAN ID of the VLAN to which the MD belongs. If the MD
port is a Layer 3 port, the frames are tagged with VLAN ID 4095. If the MD port is in a Layer 3 VLAN, the
frames are tagged with the respective Layer 3 VLAN ID. For example, in the configuration source TeGig
6/1 destination TeGig 6/2 direction tx, if the MD port TenGig 6/1 is an untagged member of any VLAN, all
monitored frames that the MG port TeGig 6/2 receives are tagged with the VLAN ID of the MD port.
Similarly, if BPDUs are transmitted, the MG port receives them tagged with the VLAN ID 4095. This
behavior might result in a difference between the number of egress packets on the MD port and
monitored packets on the MG port.
Dell Networking OS Behavior: The platform continues to mirror outgoing traffic even after an MD
participating in spanning tree protocol (STP) transitions from the forwarding to blocking.
Configuring Port Monitoring
To configure port monitoring, use the following commands.
1. Verify that the intended monitoring port has no configuration other than no shutdown, as shown in
the following example.
EXEC Privilege mode
754
Port Monitoring

Table of Contents

Other manuals for Dell S4820T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S4820T and is the answer not in the manual?

Dell S4820T Specifications

General IconGeneral
BrandDell
ModelS4820T
CategorySwitch
LanguageEnglish

Related product manuals