File Copy Setting Fault Description:
These faults occur when KPC-CC01 cannot perform the command after clicking the ENTER key in the
copy function.
LCD Display * Fault Name Description Corrective Actions
Read only
(ERR1)
Parameter and file
are read-only
The parameter / file is read-only and cannot be
written to.
1. Verify the specification in the user manual.
If this solution does not work, contact your local
authorized dealer for assistance.
Write in error
(ERR2)
Fail to write
parameter and file
An error occurred while writing to a parameter /
file.
1. Check for any problem on the Flash IC.
2. Shut down the system, wait for ten minutes,
and then restart the system.
If this solution does not work, contact your local
authorized dealer for assistance.
Drive operating
(ERR3)
AC motor drive is in
operating status
A setting cannot be changed while the motor
drive is in operation.
1. Verify that the drive is not in operation.
If this solution does not work, contact your local
authorized dealer for assistance.
Parameter
locked
(ERR4)
AC motor drive
parameter is locked
A setting cannot be changed because a
parameter is locked.
1. Check if the parameter is locked. If it is
locked, unlock it and try to set the parameter
again.
If this solution does not work, contact your local
authorized dealer for assistance.
Parameter
changing
(ERR5)
AC motor drive
parameter is
changing
A setting cannot be changed because a
parameter is being modified.
1. Check if the parameter is being modified. If it
is not being modified, try to change that
parameter again.
If this solution does not work, contact your local
authorized dealer for assistance.
Fault code
(ERR6)
Fault code is not
cleared
A setting cannot be changed because an error
has occurred in the motor drive.
1. Check if any error occurred in the motor
drive. If there is no error, try to change the
setting again.
If this solution does not work, contact your local
authorized dealer for assistance.
Warning code
(ERR7)
Warning code is not
cleared
A setting cannot be changed because of a
warning message given to the motor drive.
1. Check if there is a warning message given to
the motor drive.
If this solution does not work, contact your local
authorized dealer for assistance.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Plus Series and is the answer not in the manual?

Delta C2000 Plus Series Specifications

General IconGeneral
BrandDelta
ModelC2000 Plus Series
CategoryDC Drives
LanguageEnglish

Related product manuals