54
Remote Operation
7.5.6 SYST:GPIBADDRESS?
Syntax
SYSTem:GPIBADDRESS?
Description
This command will return the matrix’s GPIB address.
Possible values are 1 to 30
Possible error codes
5
Factory default value
9
Power on behavior
Keeps last value
*RST effect
None
7.5.7 SYST:GPIBADDRESS x
Syntax
SYSTem:GPIBADDRESS x
Description
This command will set the GPIB address to x.
Possible values for x are 1 to 30.
Possible error codes
5
Factory default value
9
Power on behavior
Keeps last value
*RST effect
None