[023] Panel Absent Trouble
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur when communications with the panel have been lost
for more than 60 seconds.
[024] Panel Absent Trouble Restore
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur when communications with the control panel have
resumed.
[025] Radio Activation Restore
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur in North American cellular communicators when the
unit has been programmed by Connect 24.
System Test Options
Test Transmissions to Primary Receiver, with Backup to Secondary Receiver:
Set Ethernet section [026] to (FF); [027] to (00). Set cellular section [028] to (FF); [029] to (00).
l If the test transmission fails to the primary receiver it will back up to the secondary receiver.
l If the test transmission fails to the secondary receiver an FTC trouble will be generated.
Test Transmission Unique to Primary and Secondary Receivers:
Set Ethernet section [026] to (FF); [027] to (FF).Set cellular section [028] to (FF); [029] to (FF).
l The module will send periodic test transmissions to each receiver independently, with no backups.
l If the test transmission fails to any of the programmed receivers, an FTC trouble will be generated.
Alternate Test Transmission:
Alternate test transmission can be enabled or disabled in section [005] toggle option [7].
Alternate Test Transmission with Backup Receivers:
Set Ethernet section [026] to (FF); [027] to (00). Set cellular section [028] to (FF); [029] to (00).
Interval 1:
l If the test transmission fails to the primary receiver, it will back up to the secondary receiver.
l If the test transmission fails to the secondary receiver, an FTC trouble will be generated.
Interval 2:
l If the test transmission fails to the secondary receiver, it will back up to the primary receiver.
l If the test transmission fails to the primary receiver, an FTC trouble will be generated.
Test Transmission Unique to Primary and Secondary Receivers:
Set Ethernet section [026] to (FF); [027] to (FF).Set cellular section [028] to (FF); [029] to (FF).
Interval 1:
l The module will send periodic test transmissions to primary receivers (Ethernet primary and cellular primary) inde-
pendently, with no backups.
l If the test transmission fails to any of the programmed primary receivers, an FTC trouble will be generated
Interval 2:
The module will send periodic test transmissions to secondary receivers (Ethernet secondary and cellular secondary) inde-
pendently, with no backups.
l If the test transmission fails to any of the programmed secondary receivers, an FTC trouble will be generated
[026] Ethernet 1 Test Transmission
Default (FF)
Program 00 to disable this event transmission or FF to enable. See System Test Options (previous page) for details on set-
tings.
[027] Ethernet 2 Test Transmission
Default (00)
Program 00 to disable this event transmission or FF to enable. See System Test Optios (previous page) for details on set-
tings.
[028] Cellular 1 Test Transmission
Default (FF)
Program 00 to disable this event transmission or FF to enable. See System Test Options (previous page) for details on set-
tings.
27

Table of Contents

Other manuals for DSC PowerSeries Neo 3G2080E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries Neo 3G2080E and is the answer not in the manual?

DSC PowerSeries Neo 3G2080E Specifications

General IconGeneral
BrandDSC
ModelPowerSeries Neo 3G2080E
CategoryCell Phone
LanguageEnglish

Related product manuals