[029] Cellular 2 Test Transmission
Default (00)
Program 00 to disable this event transmission or FF to enable. See System Test Options (previous page) for details on set-
tings.
NOTE: The time interval (in minutes) between periodic tests is programmed in section [125] (Ethernet) and section [225]
(cellular).
[030] FTC Restore
Default (FF)
Program 00 to disable this event transmission or FF to enable. This event will occur when an FTC Trouble on the system
restores.
[033] Communicator Firmware Update Begin
Default (FF)
Program 00 to disable this event transmission or FF to enable. This event will occur when a communicator firmware update
begins.
[034] Communicator Firmware Update Success
Default (FF)
Program 00 to disable this event transmission or FF to enable. This event will occur when a communicator firmware update
has completed successfully.
Table 10: System Firmware Update Failure
Event
SIA
Identifier
SIA
ReportingCode
CID
Qualifier
CID
Event
Code
CID
Reporting
Code
CID
User/Zone
[037] System FW Update Fail LU 0000 1 9 04 003
NOTE: The communicator will report ´System Update Fail´ only if the panel goes offline after a remote firmware update ses-
sion has started.
[095] SA Incoming Local Port
Default (0C14/3092)
[096] SA Outgoing Local Port
Default (0C14/3093)
[097] SA Call Up IP
Default (000.000.000.000)
[098] SA Call Up Port
Default (0000)
[099] SA Password
Default (FFFFFFFF)
Ethernet Receiver 1 Options
[101] Ethernet Receiver 1 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. This account code is used when trans-
mitting heartbeat signals to the central station receiver. Signals received from the panel will use the control panel account
number.Valid range: 0000000001-FFFFFFFFFE. Programming all 0’s or all F’s will cause a module configuration trouble.
NOTE: If Ethernet receiver 1 and cellular receiver 1 are programmed as the same receiver (IP and port number are
identical), Ethernet receiver 1 account code will be used.
[102] Ethernet Receiver 1 DNIS
Default (000000)
The Dialed Number Information Service (DNIS) is used in addition to the account code to identify the communicator module
at the central station. Valid range: 000000 - 099999. Value is entered as a leading 0 followed by the 5-digit DNIS.
[103] Ethernet Receiver 1 Address
Default (127.000.000.001)
The default address enables the communicator to operate in Unattended mode.
28

Table of Contents

Other manuals for DSC PowerSeries Neo 3G2080E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries Neo 3G2080E and is the answer not in the manual?

DSC PowerSeries Neo 3G2080E Specifications

General IconGeneral
BrandDSC
ModelPowerSeries Neo 3G2080E
CategoryCell Phone
LanguageEnglish

Related product manuals