[023] Panel Absent Trouble
Default (FF); Program 00 disable or FF enable.
[024] Panel Absent Trouble Restore
Default (FF) Program 00 disable or FF enable.
[025] Radio Activation Restore
Default (FF) Program 00 disable or FF enable.
System Test Options
[026] Ethernet 1 Test Transmission
Default (FF) Program 00 disable or FF enable.
[027] Ethernet 2 Test Transmission
Default (00) Program 00 disable or FF enable.
[028] Cellular 1 Test Transmission
Default (FF) Program 00 disable or FF enable.
[029] Cellular 2 Test Transmission
Default (00) Program 00 disable or FF enable.
[030] FTC Restore
Default (FF) Program 00 disable or FF enable.
[033] Communicator Firmware Update Begin
Default (FF) Program 00 disable or FF enable.
[034] Communicator Firmware Update Success
Default (FF) Program 00 disable or FF enable.
[095] SA Incoming Local Port
Default (0C14/3092) Valid range: 0000 - FFFF.
[096] SA Outgoing Local Port
Default (0C15/3093) Valid range: 0000 - FFFF.
[097] SA User Call Up IP
Default (000.000.000.000)
[098] SA User Call Up Port
Default (0000) Valid range: 0000 - FFFF.
[099] SA Password
Default (FFFFFFFF) Valid range: 00000000 - FFFFFFFF.
Ethernet Receiver 1 Options
[101] Ethernet Receiver 1 Account Code
Default (0000000000)
Valid range:0000000001 - FFFFFFFFFE.
[102] Ethernet Receiver 1 DNIS
Default (000000) Valid range: 000000 - FFFFFF.
[103] Ethernet Receiver 1 Address
Default (127.000.000.001)
[104] Ethernet Receiver 1 UDP Remote Port
Default (0BF5/3061) Valid range: 0000 - FFFF.
[105] Ethernet Receiver 1 UDP Local Port
Default (0BF4/3060)Valid range: 0000 - FFFF.
[106] Ethernet Receiver 1 Domain Name
Default () 32 ASCII characters.
________________________________
Ethernet Receiver 2 Options
[111] Ethernet Receiver 2 Account Code
Default (0000000000)
Valid range:0000000001 - FFFFFFFFFE.
[112] Ethernet Receiver 2 DNIS
Default (000000) Valid range: 000000 - 0FFFFF.
[113] Ethernet Receiver 2 Address
Default (000.000.000.000)
[114] Ethernet Receiver 2 UDP Remote Port
Default (0BF5/3061) Valid range: 0000 - FFFF.
[115] Ethernet Receiver 2 UDP Local Port
Default (0BF9/3065) Valid range: 0000 -FFFF.
[116] Ethernet Receiver 2 Domain Name
Default () 32 ASCII characters.
____________________________________
Ethernet Options
[124] Ethernet Test Transmission Time
Default (9999) Valid: 00-23(HH); 00-59(MM)
[125] Ethernet Test Transmission Cycle
Default (000000)
Valid range:000000 - 999999 minutes.
49

Table of Contents

Other manuals for DSC PowerSeries Neo 3G2080E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PowerSeries Neo 3G2080E and is the answer not in the manual?

DSC PowerSeries Neo 3G2080E Specifications

General IconGeneral
BrandDSC
ModelPowerSeries Neo 3G2080E
CategoryCell Phone
LanguageEnglish

Related product manuals