SOI/DT 2005-01 dmm 599 36 82-57
24/67
9.8 Rinses of Cotton / Linen programmes: 90 Eco, 40-60 “energy label” (without options)
9.8.1 For programmes with two rinses
Motor Movement CYCLE
N.° PHASE Description Drain pump
Recirc.
Pump
Deterg.
Disp
Rpm Movem. Pause 90 60 40
34 Water fill Level OFF OFF BL NO mov COT_FIRST_E_R_LEV
35 Maintenance & Refill Time OFF ON (35/15) W 55 8 8
5 min.
COT_REF_E_R_LEV
36 Drain Time ON OFF NO mov Empty Elect.+ 14 sec.
37
1
st
Rinse
Spin Time ON OFF C1 5 min. with AS control
38 Water fill Level OFF OFF SF NO mov COT_LAST_E_R_LEV
39 Maintenance Time OFF OFF 55 8 8 30 sec.
40 Water fill Level OFF OFF SF NO mov Qsf (4 Litres)
41 Maintenance & Refill Time OFF ON (35/15) W 55 8 8
4 min.
COT_REF_E_R_LEV
42 Maintenance & Refill Time OFF ON (35/15) W 55 8 8
4 min.
COT_REF_E_R_LEV
43 Drain Time ON OFF NO mov Empty Elect.+ 14 sec
44
Last rinse (softener)
Spin Time ON OFF C1 5 min. with AS control
(The data are indicative)
BL = Bleach SF = Softener W = Wash AS = Anti-foam control
9.8.2 For programmes with three rinses
Motor Movement CYCLE
N.° PHASE Description Drain pump
Recirc.
Pump
Deterg.
Disp
Rpm Movem. Pause 90 60 40
34 Water fill Level OFF OFF BL NO mov COT_FIRST_E_R_LEV
35 Maintenance & Refill Time OFF ON (35/15) W 55 8 8
5 min.
COT_REF_E_R_LEV
36 Drain Time ON OFF NO mov Empty Elect.+ 14 sec.
37
1
st
Rinse
Spin Time ON OFF C1 5 min. with AS control
38 Water fill Level OFF OFF W NO mov COT_INT_E_R_LEV
39 Maintenance & Refill Time OFF ON (35/15) W 55 8 8
5 min.
COT_REF_E_R_LEV
40 Drain Time ON OFF NO mov Empty Elect.+ 14 sec.
41
2
nd
Rinse
Spin Time ON OFF C1 5 min. with AS control
42 Water fill Level OFF OFF SF NO mov COT_LAST_E_R_LEV
43 Maintenance Time OFF OFF 55 8 8 30 sec.
44 Water fill Level OFF OFF SF NO mov Qsf (4 Litres)
45 Maintenance & Refill Time OFF ON (35/15) W 55 8 8
8 min.
COT_REF_E_R_LEV
46 Drain Time ON OFF NO mov Empty Elect.+ 14 sec
47
Last rinse
(softener)
Spin Time ON OFF C1 5 min. with AS control
(The data are indicative)
BL = Bleach SF = Softener W = Wash AS = Anti-foam control