Markings:
II 3 D Ex tc IIIC T135 °C Dc, (-40 °C ≤ T
a
≤ +65 °C)
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic
charge build-up, it must not be rubbed with a dry cloth or cleaned with solvents.
B.9 International
N7 IECEx Type n
Certificate:
IECEx BAS 07.0012X
Standards:
IEC 60079-0: 2011, IEC 60079-15: 2010
Markings:
Ex nA IIC T4 Gc, T4(–40 °C ≤ T
a
≤ +65 °C), V
MAX
= 28Vdc
Special Conditions for Safe Use (X):
1. The apparatus is not capable of withstanding the 500 V electrical strength test as
defined in Clause 6.5.1 of IEC 60079-15:2012. This must be taken into account
during installation.
2. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic
charge build-up, it must not be rubbed with a dry cloth or cleaned with solvents.
NF IECEx Dust
Certificate:
IECEx BAS 07.0013X
Standards:
IEC 60079-0: 2011, IEC 60079-31: 2008
Markings:
Ex tc IIIC T135 °C Dc, (–40 °C ≤ T
a
≤ +65 °C)
Special Conditions for Safe Use (X):
1. The surface resistivity of the antenna is greater than 1 GΩ. To avoid electrostatic
charge build-up, it must not be rubbed with a dry cloth or cleaned with solvents.
B.10 Brazil
N2 UL-BR 15.0350X
Certificate:
UL-BR 15.0350X
Standards:
ABNT NBR IEC 60079-0:2008 + Errata 1:2011, IEC 60079-15:2012
Markings:
Ex nA IIC T4 Gc, T4(–40°C ≤ T
a
≤ +65°C)
Special Conditions for Safe Use (X):
1. See certificate for special conditions.
Reference Manual Product Certifications
00809-0200-4420 September 2020
Emerson.com/Rosemount 77