104
Operator's instructions
8. Options
Use and maintenance
The installation of a BPF R620 system does not change the use and the maintenance of the engine.
The maintenance intervals indicated by the vehicle/engine manufacturer for the other systems do not
change and must be strictly respected.
For the functioning of the BPF R620 systems is mandatory to take care of the indications of the status
LED. The following indications must be strictly observed:
System status
The status LED shows with its signaling the status
of the system when the engine is running. The
indications of the LED and their meanings are
showed in the following:
FIXED GREEN: normal operation.
FIXED RED: high pressure alarm.
BLINKING RED: low pressure alarm.
BLINKING RED/GREEN: high pressure alarm
and low pressure alarm acknowledged.
DOUBLE BLINKING RED: pressure warning
TRIPLE BLINKING RED: warning inlet temperature, warning outlet temperature, warning
additional temperature, warning additive pump, warning aided regeneration device (glow plugs),
warning plausibility checks, warning additional pressure (if no other signal is active).
QUADRUPLE BLINKING RED: closed additional relay.
QUINTUPLE BLINKING RED: ALARM MEMORY full.
DOUBLE BLINKING RED / DOUBLE BLINKING GREEN: low additive level.
TRIPLE BLINKING RED / TRIPLE BLINKING GREEN: maintenance interval achieved.
BLINKING GREEN: manual ignition of the aided regeneration device (glow plugs) in progress.
The high pressure alarm and low pressure alarm must be acknowledged from the operator by pressing
the pushbutton. After the acknowledgement, the signaling of the LED changes (it becomes
BLINKING RED/GREEN).
If a high pressure alarm or low pressure alarm is acknowledged, it will end at the engine shut down
or at the BYBOX power off.
If a high pressure alarm or low pressure alarm is not acknowledged, it will remain active and signaled
by the LED even after the engine shut down and restart, or after the power off and on of the BYBOX.