- (01-188) -
MULTI TYPE
2, 3, 4 ROOMS TYPE
MULTI TYPE
2, 3, 4 ROOMS TYPE
INSTALLATION PRECAUTIONS15.
INDOOR UNIT INSTALLATION PRECAUTIONS15-1.
Note: The information listed below are general precautions.
Some models also include items that do not apply.
PLACES WHERE USE IS PROHIBITED
•Places where there is danger of combustible gas leakage.
•Places where sulfur gas, chlorine gas, acid, alkali, or other matter which effects equipment is
generated
•Places where there is a lot of oil splash and steam (kitchen, machinery room, etc.)
•Places where machinery which generates high frequencies is used
Ocean beaches and other areas where there is a lot of salt
•Places where carbon bers and metal powder, powder, etc. is suspended in the air
•Installation in vehicles, ships, and other conveyances
•Factory, etc. where voltage uctuations are large
POINTS TO REMEMBER WHEN INSTALLING
(1) The set shall be installed at a place which can withstand the weight and vibration of the indoor
unit
(2) To allow maintenance after refrigerant piping, drain piping, and electric wiring connection and
installation, provide an installation service space and an inspection port, as required.
*Installation service space is shown on " DIMENSIONS ".
(3) Be careful when installing the set at the following places.
[Installation precautions]
Contents
Countermeasures
(Reference)
When the
ceiling is high
If the indoor unit is installed where the installation height
given in the installation manual is exceeded, the temperature
difference between the oor and ceiling of the room will be
large and the heating effect will be poor.
Moreover, even if the indoor unit is installed within the
installation height, a similar phenomena will occur when
installed in a room in which the doors are opened and closed
frequently and hot air circulation is obstructed by desks, chairs,
etc.
(1) Switch the setting to the high
ceiling mode.
(2) Install a circulator.
(3) Arrange the furniture in the
room so that it does not
obstruct the hot air.
When lower level
is in direct contact
with outside air.
When the lower level of shops and ofces is a warehouse,
parking lot, etc., the surface temperature of the ooring
will become low and cold radiation from the oor will increase.
In this case, your feet will feel cold even if the room
temperature is suitable.
When the air
ow distribution
is poor
When an indoor unit is installed in a position where the outlet
air ow will directly contact people, a draft may be felt.
In addition, when there are obstructions in the path of the
intake and outlet air ow, the air distribution may become
extremely bad.
(1) Adjust the louver ns or take
other measures matched to
the site.
(2)Change the indoor unit outlet.

Table of Contents

Other manuals for Fujitsu AB*G14LVTA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AB*G14LVTA and is the answer not in the manual?

Fujitsu AB*G14LVTA Specifications

General IconGeneral
BrandFujitsu
ModelAB*G14LVTA
CategoryAir Conditioner
LanguageEnglish

Related product manuals