FLOOR / CEILING TYPE3-4.
Model name AB
G14LVTA
AB
G18LVTA
AB
G18 LV TB
Power source 1ø 230V ~ 50Hz
Available voltage range 198-264V
Capacity 4.0kW Class 5.0kW Class
Input power W 26 47
Running current A 0.21 0.36
Fan
Airow
rate
Cooling
High
m
3
/h
640 780
Med 590 700
Low 540 560
Quiet 480 500
Heating
High 640 780
Med 590 700
Low 540 560
Quiet 480 500
Type × Q'ty Sirocco x 2
Motor output W 80
Sound pressure level *
Cooling
High
dB(A)
36 (Under ceiling)
39 (Floor console)
41 (Under ceiling)
44 (Floor console)
Med
34 (Under ceiling)
37 (Floor console)
38 (Under ceiling)
41 (Floor console)
Low
33 (Under ceiling)
36 (Floor console)
34 (Under ceiling)
37 (Floor console)
Quiet
29 (Under ceiling)
32 (Floor console)
32 (Under ceiling)
35 (Floor console)
Heating
High
36 (Under ceiling)
39 (Floor console)
41 (Under ceiling)
44 (Floor console)
Med
34 (Under ceiling)
37 (Floor console)
38 (Under ceiling)
41 (Floor console)
Low
33 (Under ceiling)
36 (Floor console)
34 (Under ceiling)
37 (Floor console)
Quiet
29 (Under ceiling)
32 (Floor console)
32 (Under ceiling)
35 (Floor console)
Sound power level
Cooling 51 55
Heating 51 55
Heat
exchanger
Dimension (H × W × D)
mm
252 × 800 × 26.6 252 × 800 × 39.9
Fin pitch 1.2 1.3
Rows × Stages 2 × 12 3 × 12
Pipe type Copper tube
Fin Type Aluminium
Enclosure
Material ABS
Colour
WHITE
(Approximate colour of MUNSELL N9.25)
Dimensions
(H × W × D)
Net
mm
199 × 990 × 655
Gross 320 × 1150 × 790
Weight
Net
kg
27
Gross 36
Connection
pipe
Size
Liquid
mm
Ø6.35 (Ø1/4in.)
Gas Ø12.70 (Ø1/2in.)
Method Flare
Drain hose
Material Hard PVC
size mm Φ25 (I.D.), Φ32 (O.D.)
Operation range
Cooling
°C 18 to 32
%RH 80 or less
Heating °C 16 to 30
Remote controller type Wireless [Wired (option)]
NOTE:
The protective function may work when using it outside the operation range.
*: These are the measured values in the manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than
the specied values here.