OUTDOOR UNIT
AO
G30L4
OUTDOOR UNIT
AO
G30L4
SPECIFICATIONS1.
The following performance is a value at standard combinations.
STANDARD COMBINATION
AO
G30LAT4 : AS
G09LMCA + AS
G09LMCA + AS
G09LMCA + AS
G09LMCA
Type
INVERTER MULTI MODELS
HEAT PUMP TYPE
Model name AO
G30 LAT4
Power source 230V ~ 50Hz
Available voltage range 198-264V ~ 50Hz
Capacity
Cooling
Rated
kW 8.0
Btu/h 27300
Min. - Max.
kW 3.5 - 10.1
Btu/h 11940 - 34500
Heating
Rated
kW 9.6
Btu/h 32800
Min. - Max.
kW 3.7 - 12.0
Btu/h 12620 - 41000
Input power
Cooling
Rated
kW
2.22
Max. 3.56
Heating
Rated 2.40
Max. 3.58
Current
Cooling
Rated A
9.7
Heating 10.5
EER Cooling
Rated
kW/kW 3.60
COP Heating kW/kW 4.00
Starting current A 10.5
Maximum operating current A 15.5
Fan
Airow rate
Cooling
m
3
/h
3500
Heating 3300
Type x Q'ty Propeller × 1
Motor output W 103
Sound pressure level *1
Cooling
dB(A)
50
Heating 51
Heat
exchanger
type
Dimension (H × W × D) mm 798 × 900 × 36.38
Fin pitch mm 1.3
Rows x Stages 2 × 38
Pipe type Copper tube
Fin type Aluminium
Compressor
Type x Q'ty DC TWIN ROTARY × 1
Motor output W 1300
Refrigerant
Type (Global Warming Potential) R410A (1975)
Charge g 3300
Refrigerant oil Type POE
Enclosure
Material Steel sheet
Colour
BEIGE
(Approximate colour of MUNSELL 10YR7.5 / 1.0NN)
Dimensions
(H ×W ×D)
Net
mm
830 × 900 × 330
Gross 970 × 1050 × 445
Weight
Net
kg
68
Gross 75
Connection pipe
Size
Liquid
mm
Ø6.35 (Ø1/4 in.) × 4
Gas Ø9.52 (Ø3/8 in.) × 2, *2) Ø12.70 (Ø1/2 in.) × 2
Method Flare
Pre-charge length (Total)
m
50
Max. length (Total) 70
Max. length (Each) 25
Min. length (Total) 20
Min. length (Each) 5
Max. height difference between
Outdoor Unit and each Indoor Units.
15
Max. height difference between Indoor Units. 10
Operation range
Cooling
°C
0 to 46
Heating -10 to 24
NOTE:
Specications are based on the following conditions.
Cooling: Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB / 24 °CWB.
Heating: Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB / 6 °CWB.
Pipe length: 5 m, Height difference: 0 m. (Outdoor unit - indoor unit)
The protective function might work when using it outside the operation range.
*1: These are the measured values in the manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specied
values here.
*2: Connect to connection valve by the adapter