- (01-48) -
MULTI TYPE
2, 3, 4 ROOMS TYPE
MULTI TYPE
2, 3, 4 ROOMS TYPE
FLOOR TYPE3-5.
Model name AG
G09LVCA AG
G12LVCA AG
G14LVCA
Power source 1ø 230V ~ 50Hz
Available voltage range 198-264V
Capacity 2.5kW Class 3.5kW Class 4.0kW Class
Input power W 16 20 23
Running current A 0.15 0.18 0.20
Fan
Airow
rate
Cooling
High
m
3
/h
530 600 650
Med 440 490 520
Low 360 380 400
Quiet 270 270 270
Heating
High 530 600 650
Med 460 510 540
Low 380 410 430
Quiet 270 270 270
Type × Q'ty Crossow x 2
Motor output W 42
Sound pressure level *
Cooling
High
dB(A)
39 42 44
Med 34 36 38
Low 28 30 31
Quiet 22 22 22
Heating
High 39 42 44
Med 35 38 39
Low 30 32 33
Quiet 22 22 22
Sound power level
Cooling 52 55 56
Heating 52 55 56
Heat
exchanger
Dimension (H × W × D)
mm
378 × 550 × 26.6
Fin pitch 1.2
Rows × Stages 2 x 18
Pipe type Copper tube
Fin Type Aluminium
Enclosure
Material
Polystyrene
Colour
WHITE
(Approximate colour of MUNSELL N9.25)
Dimensions
(H × W × D)
Net
mm
600 × 740 × 200
Gross 700 × 820 × 310
Weight
Net
kg
14
Gross 17
Connection
pipe
Size
Liquid
mm
Ø6.35 (Ø1/4in.)
Gas Ø9.52 (Ø3/8in.) Ø12.70 (Ø1/2in.)
Method Flare
Drain hose
Material PVC
size mm Φ13.8 (I.D.), Φ16.7 (O.D.)
Operation range
Cooling
°C 18 to 32
%RH 80 or less
Heating °C 16 to 30
Remote controller type Wireless [Wired (option)]
NOTE:
The protective function may work when using it outside the operation range.
*: These are the measured values in the manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than
the specied values here.