1. DESCRIPTION OF OPERATION
1-20
7. Read the bearing and range indications at the bottom of the screen.
How to measure the range and bearing between two targets
When you press the OFF CENTER key in EBL operation, the origin of an EBL moves
between the screen center and cursor location. To return the origin of an EBL to the
screen center, press the ENTER key when the origin of an EBL is on the screen cen-
ter.
1.18 How to Select a Pulselength
The pulselength in use appears at the upper-left position on the screen. The pulse-
lengths are set to each range scale and custom setup. You can change the pulse-
length on the 1.5 nm, 1.6 nm, 3 nm or 3.2 nm range with the following procedure.
Pulselength cannot be changed on other ranges. (You can change the pulselength on
the 2 nm or 4 nm range in the [Russian-River] mode.) Use a longer pulse when your
purpose is long range detection. Use a shorter pulse when the resolution is important.
Note: Press the CUSTOM key several times to activate the [Echo] menu until the CS
1 (2, 3) indication (custom setting) disappears from the screen. See the illustration in
section 1.3.
1. Press the MENU key to open the menu.
EBL origin
+
+
Target B
Range/bearing between
targets A and B
Range/bearing between
targets C and D
EBL 2
VRM 2
EBL 1
VRM 1
EBL
45.0
°
R
327.0
°
R
VRM
0.550NM
0.550NM
Target A
Target D
Target C

Table of Contents

Other manuals for Furuno 1945

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno 1945 and is the answer not in the manual?

Furuno 1945 Specifications

General IconGeneral
BrandFuruno
Model1945
CategoryMarine Radar
LanguageEnglish

Related product manuals