3. TARGET TRACKING (TT)
3-18
3.12.2 Vector mode and length
Vectors can be displayed in true or relative modes. Vector lengths can be set between
30 seconds and 60 minutes.
The vector tip shows an estimated position of the target after the selected vector time
elapses. It can be valuable to extend the vector length to evaluate the risk of collision
with any target.
How to change the vector mode
Place the cursor on the vector reference indication in the [Vector] box, then left-click
to cycle through the following settings.
[REL] [TRUE-G/TRUE-S] [REL]...
How to change the vector time
Place the cursor on the vector time indication in the [Vector] box, then left-click to cycle
through the following settings.
[6min] [10min] [20min] [30min] [45min] [60min] [30sec] [1min]
[3min] [5min] [6min]...
You can also spin the scrollwheel to change the vector time in one-minute increments.
Vector time
Vector mode

Table of Contents