1. INITIAL SETTING AND ADJUSTMENT
1-54
1.7 [AMS] Menu
The AMS menu sets up the interface between the AMS (Alert Management System)
and the processor unit, including the AMS operating mode.
Note 1: For Chart Radars, only the settings on the [Operation Mode Setting] window
are required (see section 1.7.1).
Note 2: For how to set the alert definition of AMS, see the FURUNO information.
1.7.1 AMS mode operation
1. Access the [Common Installation Setting] menu, then select [AMS] from the tab
bar.
2. Select [Operation Mode Setting] on the menu bar.
[Output Route File
Format]
Select whether the channel limit is symmetrical or asymmetrical.
This setting is available when [Output Route Data Setting] is set to
[File and RMB].
• [Symmetrical]: The channel limit is symmetrical.
• [Asymmetrical]: The channel limit is asymmetrical.
[Source SFID] Select the additional SFID when CCRS outputs the sentence from
the TCS ([ECDIS SFID] or [TCS SFID]).
item Remarks
[Alert Monitoring In-
terval]
Set the time to wait before clearing the corresponding alert when
communication with a sensor is interrupted.
[Disable Alert Time-
out Clear] (01 to 05)
Select the units where the alert is not to be cleared.
[Output Data Type
For INS]
Select the data type of alert notification, ALR or ALF.
[Enable Category A
Buzzer]
Select if the alert buzzer sounds when the alert of Category A oc-
curs.
[Buzzer Pattern] Sets the buzzer sound pattern to output when an alert occurs.
[INS]:
• Alert priority = “Alarm”: Three short beeps, four seconds mute,
then repeat.
• Alert priority = “Warning”: Two short beeps, four seconds
mute, then repeat.
[Legacy]:
• Alert priority = “Alarm” or “Warning”: Alarm sounds continuous-
ly.
Menu item Description