1. INITIAL SETTING AND ADJUSTMENT
1-15
• [RCB00 (Main)] (: 1 to 4): Input the location information of the external radar
antenna that is connected to the [RADAR SIGNAL IN No.1] port.
• [RCB00 (Sub)] (: 1 to 4): Input the location information of the external radar
antenna that is connected to the [RADAR SIGNAL IN No.2] port. Set parame-
ters for the [RCB00 (Main)] before setting parameters for the [RCB00 (Sub)].
7. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
1.4 [Installation Parameters] Menu
The [Installation Parameters] menu sets the signals and input data of the sensors.
First, select the sensor data at the [Sensor Setting] window. Then select the sensor
from which the units (radar sensor (antenna unit), MFD, ECDIS, Radar, Chart Radar,
and Sensor Adapter) obtain the sensor data.
1.4.1 Sensor setting
1. Access the [Common Installation Setting] menu and click [Installation Parame-
ters] on the tab bar.
2. Click [Sensor Setting] on the menu bar, then click [GPS Sensor].
3. Check applicable check boxes according to the number of GPS receivers con-
nected.
4. Set the following items for the units activated at step 3.
Item Remarks
[SFID] Keep the default setting.
Do not use the "AI" prefix (AIS excluded) or the "II" prefix.
[Data Type] Sets the RX sentence data format.
Setting options: [IEC 61162-1 Ed3], [IEC 61162-1 Ed4], [IEC 61162-
1 Ed5], [ASCII], [BINARY], [MODBUS], [PSU]. Do not select [ASCII],
[BINARY] or [PSU].
[Strict/Loose] Sets the integrity of sentence data.
[Strict]: Confirm the validity of checksum, then receive sentence.
[Loose]: Receive sentence regardless of checksum invalidity.
The time to timeout for receiving
data. Keep the default setting.
The time to timeout for receiving
data. Keep the default setting.

Table of Contents

Other manuals for Furuno FMD-3200-BB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FMD-3200-BB and is the answer not in the manual?

Furuno FMD-3200-BB Specifications

General IconGeneral
BrandFuruno
ModelFMD-3200-BB
CategoryMarine Equipment
LanguageEnglish

Related product manuals