1-1
1. INITIAL SETTING AND
ADJUSTMENT
This chapter shows you how to enter the initial settings for the processor unit (EC-
3000) of ECDIS and Chart Radar after the installation.
Note: Each unit has a default IP address. Enter the initial settings (Equipment ID set-
ting) and change the IP address on the [Basic Setting] menu (see section 1.2.), before
connecting each unit and building the network. After entering the equipment ID(s),
build the network and enter other settings. You can enter the settings of each unit all
at one time by building the network.
1.1 How to Access the [Common Installation
Setting] Menu
The initial settings for the ECDIS and Chart Radar are performed on the [Common In-
stallation Setting] menu. The [Common Installation Setting] menu works with a web
browser.
Access the [Common Installation Setting] menu by either of the two methods shown
below.
Access on a laptop PC (LAN connection). See section 1.1.1.
Access with the control unit RCU-024/025/026. See section 1.1.2.
Note 1: Supported browsers are as follows:
• Internet Explorer
®
11
Firefox ESR 60
Note 2: To update the software with the updating file (see section 1.12.), access the
[Common Installation Setting] menu via LAN connection. To update the software with
the DVD, access the [Common Installation Setting] menu with the control unit.
Note 3: When you access the MC-3000S directly from Internet Explorer
®
, you cannot
adjust the settings on the [Alert Define List] menu. Access either the EC-3000, or use
Firefox to adjust the settings on the [Alert Define List] menu.
1.1.1 Laptop PC (LAN connection) access
1. Set the IP address and subnet mask of the PC according to the LAN port where
the PC is connected.
Note: For the Sensor Adapter, use the LAN2 port (sensor network).
LAN port
IP address/
Subnet mask
Setting value
LAN1
(Gateway network)
IP address 192.168.31.200
Subnet mask 255.255.255.0
LAN2
(Sensor network)
IP address 172.31.16.200
Subnet mask 255.255.0.0

Table of Contents

Other manuals for Furuno FMD-3200-BB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FMD-3200-BB and is the answer not in the manual?

Furuno FMD-3200-BB Specifications

General IconGeneral
BrandFuruno
ModelFMD-3200-BB
CategoryMarine Equipment
LanguageEnglish

Related product manuals