Supplied By www.heating spares.co Tel. 0161 620 6677
6
Electrical Supply Failure
The boiler will not work without an electrical supply.
Normal operation of the boiler should resume when the
electrical supply is restored.
Reset any external controls, to resume normal operation of the
central heating.
If the boiler does not resume normal operation press the reset
button. If the boiler does not resume normal operation after this
call your Installation/Servicing company.
Overheating safety
In the event of the boiler overheating the safety devices will
cause a safety shutdown. If this happens, press the reset
button.
Safety Discharge Valve
A safety discharge valve and discharge pipe is fitted to the
boiler. This valve must not be touched. Should there be any
discharge from the pipe, isolate the boiler electrical supply and
call your installer or Glow-worm’s own service organisation
using the telephone number on the inside front cover of this
booklet.
Appliance Safety Devices
Frost protection
The appliance has a built in frost protection device that pro-
tects the boiler from freezing. With the gas and electric supplies
ON and irrespective of any room thermostat setting, the frost
protection device will operate the pump when the temperature
of the boiler water falls below 8
O
C.
A timer is used so that the temperature can be checked periodi-
cally. After 10 minutes the pump will be stopped if the tempera-
ture is higher than 10
O
C or has already reached 35
O
C.
The burner will activate if the boiler temperature does not reach
10
O
C after 30 minutes or at any time if the temperature drops
to 5
O
C.
The burner will switch off when the temperature reaches
35
O
C.
Condensate Drain Blockage
As a safety feature the boiler will stop working if the condensate
drain becomes blocked. During freezing conditions this may
be due to the forming of ice in the condense drain external
to the house. Release an ice blockage by the use of warm
cloths on the pipe. The boiler should then restart. Contact your
installation/servicing company if the fault persists.
Maintenance and Servicing
Maintenance and Servicing
To ensure the continued efficient and safe operation of the
appliance it is recommended that it is checked and serviced as
necessary at regular intervals. The frequency of servicing will
depend upon the particular installation conditions and usage.
If this appliance is installed in a rented property there is a duty
of care imposed on the owner of the property by the current
issue of the Gas Safety (Installation and Use) Regulations,
Section 35.
Servicing/maintenance should be carried out by a competent
person in accordance with the rules in force in the countries
of destination.
To obtain service, please call your installer or Glow-worm’s
own service organisation using the telephone number on the
inside front cover of this literature.
Please be advised that the ‘Benchmark’ logbook, located at
centre of literature, should be completed by the installation
engineer on completion of commissioning and servicing.
Spare Parts
Remember, when replacing a part on this appliance, use
only spare parts that you can be assured conform to the
safety and performance specification that we require. Do not
use reconditioned or copy parts that have not been clearly
authorised by Glow-worm.
If a part is required contact Glow-worm’s own service
organisation using the telephone number on the inside front
cover of this booklet.
Please quote the name of the appliance, this infomation will be
on the name badge on the front of the appliance.
If in doubt seek advice from the local gas company or Glow-
worm’s own service organisation using the telephone number
on the inside front cover of this booklet.

Other manuals for Glow-worm Flexicom 18sx

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Flexicom 18sx and is the answer not in the manual?

Glow-worm Flexicom 18sx Specifications

General IconGeneral
BrandGlow-worm
ModelFlexicom 18sx
CategoryBoiler
LanguageEnglish

Related product manuals