SECURING
SCREW
SERVICE
FILL LEVEL
CONDENSATE
TRAP
13 Servicing
Diagram 13.10
13007
13.7 Condensate Trap
NOTE: If the functional checks did not indicate poor
combustion then it is not necessary to service this
component.
The condensate trap does not normally need removing during
servicing unless the service ll level is at full, see diagram
13.12.
To ush the condense drain carefully pour water into the heat
exchanger and check that water ows freely to drain.
13.8 Casing panel seal check
NOTE: If the functional checks did not indicate poor
combustion then it is not necessary to service this
component.
Check the condition of the seal and replace if worn or
damaged.
To replace remove the old seal and thoroughly clean the
casing surfaces. Fit the new seals, these are supplied to the
correct lengths and are in four pieces, for use on the sides,
top and bottom.