Shutdown and Cleaning
312001B 15
Shutdown and Cleaning
Pail Flushing
1. Relieve pressure, page 8.
2. Remove tip and guard assembly from gun and place
in flushing fluid.
3. Lift suction tube and prime tube from paint pail. Let
them drain into paint pail for a while.
4. Separate prime tube (smaller) from
suction tube (larger).
5. Place waste and paint
pails side by side.
6. Place prime tube in waste pail.
7. Submerge suction tube in
water or flushing solvent.
8. Turn pressure control knob to
the Prime/Clean setting.
9. Turn power switch ON.
10. Flush until approximately 1/3 of the flushing fluid is
emptied from the pail.
11. Turn power switch OFF.
• For short term shutdown periods (overnight to
two days) refer to Short Term Storage, page 20.
• For flushing after spraying oil-based coatings,
use compatible oil-based flushing fluid or min-
eral spirits. Read Priming and Flushing Storage
Fluid, page 9.
• For flushing after spraying water-based coat-
ings, use water. Read Priming and Flushing
Storage Fluid, page 9 or Power Flush, page 17.