Repair
Calibration P
rocedure
NOTICE
To prevent damage to the heated hose, a hose
calibration is required if any of the following
conditions are true:
• The hose has never been calibrated before.
• A section of hose has been replaced.
• A section of hose has been added.
• A section of hose has been removed.
NOTE: The Reactor and heated hose must be at the
same ambient temperature to get the most accurate
calibration.
1. Enter Set
up Mode and navigate to System
screen 3, then press the Calibrate soft key
.
2. Press the Continue soft key to acknowledge
the reminder to have the hose at ambient
conditions.
3. Wait while the system measures the hose
resistance.
NOTE: If hose heat was on prior to the calibration
procedure, the system will wait up to five minutes
to allow the wire temperature to equalize.
NOTE: The hose temperature must be above 32
°F (0 °C) during calibration.
333024N 75