Models
Models
Reactor 2 E-30 and E-30 Elite
All elite sys
tems include fluid inlet sensors, ratio monitoring, and Xtreme-Wrap 50 ft (15 m) heated hose. For
part numbers
,seeAccessories, page 11
E-30 Model E-30 Elite Model
Model
10 kW 15 kW 10 kW 15kW
Proportioner ★ 272010 272011 272110 272111
Maximum Fluid Working
Pressure psi (MPa, bar)
2000 (14, 140) 2000 (14, 140) 2000 (14, 140) 2000 (14, 140)
Approximate Output per
Cycle (A+B) gal. (liter)
0.0272 (0.1034) 0.0272 (0.1034) 0.0272 (0.1034) 0.0272 (0.1034)
Max Flow R
ate lb/min
(kg/min)
30 (13.5) 30 (13.5) 30 (13.5) 30 (13.5)
Total Sy
stem Load † ◊
(Watts)
17,900 23,000 17,900 23,000
Configu
rable Voltage
Phase ◊
200
–240
VAC
1Ø
200
–240
VAC
3Ø∆
350
–415
VAC
3ØY
200
–240
VAC
1Ø
200
–240
VAC
3Ø∆
350
–415
VAC
3ØY
200
–240
VAC
1Ø
200
–240
VAC
3Ø∆
350
–415
VAC
3ØY
200
–240
VAC
1Ø
200
–240
VAC
3Ø∆
350
–415
VAC
3ØY
Full Load Peak Current*
78 50 34 100 62 35 78 50 34 100 62 35
Fusion AP Package ‡
(Gun Part No.)
AP2010
(246102)
AH2010
(246102)
AP2011
(246102)
AH2011
(246102)
AP2110
(246102)
AH2110
(246102)
AP2111
(246102)
AH2111
(246102)
Fusion CS Package ‡
(Gun Part No.)
CS2010
(CS02RD)
CH2010
(CS02RD)
CS2011
(CS02RD)
CH2011
(CS02RD)
CS2110
(CS02RD)
CH2110
(CS02RD)
CS2111
(CS02RD)
CH2111
(CS02RD)
Probl
er P2 Package ‡
(Gun P
art No.)
P22010
(GCP2R2)
PH2010
(GCP2R2)
P22011
(GCP2R2)
PH2011
(GCP2R2)
P22110
(GCP2R2)
PH2110
(GCP2R2)
P22111
(GCP2R2)
PH2111
(GCP2R2)
24K240 24K240 24K240 24K240 24Y240 24Y240 24Y240 24Y240Heated Hose
50 ft (15 m)
24K240 (scuff guard)
24Y240 (Xtreme-Wrap)
Qty: 1 Qty: 5 Qty: 1 Qty: 5 Qty: 1 Qty: 5 Qty: 1 Qty: 5
Heated Whip Hose
10 ft (3 m)
246050 246050 246050 246050
Ratio Monitoring
✓✓
Flu
id Inlet Sensors (2)
✓✓
*
Full load amps with all devices operating at
maximum capabilities. Fuse requirements at
various flow rates and mix chamber sizes may be
less.
†
Total system watts used by system, based on
maximum heated hose length for each unit.
• E–30 and E–XP2 series: 310 ft (94.5 m)
maximum heated hose length, including whip
hose.
★
Se
e Approvals, page 11.
‡
Packages include gun, heated hose, and whip
hose. Elite packages also include ratio monitoring
and fluid inlet sensors.
◊
Low line input voltage will reduce power available
and heaters will not perform at full capacity.
Voltage Configurations Key
Ø
Phase
∆
DELTA
YWYE
333024N 9