10
INSTALLATION
Installing Hand Chain
• Use 5mm long link chain only
• Ensure the mounting position allows the hand chain to hang free of obstructions
• Ensure hand chain is not twisted when re-making the join
CAUTION
Motor
may become hot during operation. Appropriate clearance and/or shielding should be supplied by the installer to ensure any
cabling, wiring and/or other items cannot come in contact with the motor. If temperature rise exceeds 50°C all cable wiring must be
shrouded.
Fixed wiring insulation must be protected, for example, by insulating sleeving having an appropriate temperature rating.
Automatic Chain Engagement Mechanism (ACEM)
The patented ACEM feature allows the use of the hand chain at all times when the motor is not in use and in the event of
a power failure. Simply pull on the hand chain in either direction to operate the door manually.
Warning! Ensure power is isolated when using this feature.
The ACEM label (see right) must be fixed in close proximity to the controller e.g. on the door track.