EasyManuals Logo
Home>Growatt>Inverter>MIN 2500TL-X

Growatt MIN 2500TL-X User Manual

Growatt MIN 2500TL-X
51 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
37
7.3 Advanced setting
7.3.1 Reset Country
Single touch to switch display or make the number +1.
Double touch to confirm you setting.
The password of advanced setting is 123.
Set Country
VDE0126
Set Country
xxxxxxx
Set OK
Set parameter
General
Advanced
Password
123
7.3.2 Export limitation setting
Single touch to switch display or make the number +1.
Double touch to confirm you setting.
Exporlimit
OFF ON
Meter
CT
Set OK
Set parameter
General
Advanced
Password
123
7.3.3 Reset factory
Information
Perform this operation with caution because all configured parameters
except the current date,time, and model parameters will be restored to
their factory defaults.

Other manuals for Growatt MIN 2500TL-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt MIN 2500TL-X and is the answer not in the manual?

Growatt MIN 2500TL-X Specifications

General IconGeneral
Product colorWhite
Overvoltage categoryCAT II
Power protection featuresOver voltage, Reverse polarity, Short circuit
International Protection (IP) codeIP65
Noise level35 dB
Product type-
Maximum power2500 W
Output current13.3 A
DC input voltage500 V
Number of phases1
Output frequency50/60 Hz
Starting voltage100 V
MPP voltage range80 - 500 V
Output power capacity (max)- kVA
Input operation voltage (min)80 V
Output operation voltage (max)280 V
Output operation voltage (min)180 V
Operating temperature (T-T)-25 - 60 °C
Wi-FiYes
Display technologyOLED
Weight and Dimensions IconWeight and Dimensions
Depth160 mm
Width375 mm
Height350 mm
Weight10800 g