8 Start-Up and shut down the inverter
8.1 Start-Up the inverter
1. Connect the AC breaker of the inverter.
2. Turn on the dc switch, and the inverter will start automatically when the input
voltage is higher than 70 V.
8.2 Turn-off the Inverter
DANGER
Do not disconnect the DC connectors under load.
Turn-off the inverter step:
1. Disconect the line circuit breaker from single-phases grid and prevent it from
being reactivated.
2. Turn off the dc switch.
3. Check the inverter operating status.
4. Waiting until LED, OLED have go out, the inverter is shut down.
9 Maintenance and Cleaning
9.1 Checking Heat Dissipation
If the inverter regularly reduces its output power due to high temperature,
please improve the heat dissipation condition. Maybe you need to clean the
heat sink.

Other manuals for Growatt MIN 2500TL-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt MIN 2500TL-X and is the answer not in the manual?

Growatt MIN 2500TL-X Specifications

General IconGeneral
Product colorWhite
Overvoltage categoryCAT II
Power protection featuresOver voltage, Reverse polarity, Short circuit
International Protection (IP) codeIP65
Noise level35 dB
Product type-
Maximum power2500 W
Output current13.3 A
DC input voltage500 V
Number of phases1
Output frequency50/60 Hz
Starting voltage100 V
MPP voltage range80 - 500 V
Output power capacity (max)- kVA
Input operation voltage (min)80 V
Output operation voltage (max)280 V
Output operation voltage (min)180 V
Operating temperature (T-T)-25 - 60 °C
Wi-FiYes
Display technologyOLED
Weight and Dimensions IconWeight and Dimensions
Depth160 mm
Width375 mm
Height350 mm
Weight10800 g

Related product manuals