Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

%,+#9%+A:!/.(.+!+A9.:
The heater will automatically reset when an error condition is corrected and resume operation as detailed
in the table below. The heater can be manually reset using the keypad by cycling the mode button through
³67$1'%<´DQGEDFNWRWKHRULJLQDORSHUDWLQJPRGH³63$´RU³322/´
"./A#'A:!A&(".:+A#&]
The heater is designed and built for long performance life when installed and operated according to the
PDQXIDFWXUHUVGLUHFWLRQV5HJXODULQVSHFWLRQE\TXDOL¿HGVHUYLFHSHUVRQQHOLVUHFRPPHQGHGWRNHHSWKH
heater working properly. The following inspection points are suggested to help maximize heater life.
1. Periodically check the venting on outdoor heaters. The heater’s venting areas (the louvered top panel)
must never be obstructed in any way and minimum clearances must be observed to prevent restric-
tion of combustion and ventilation air. Remember that shrubs grow and in time may obstruct a heaters
venting areas.
 &KHFNWKHYHQWLQJRILQGRRUKHDWHUVIRUORRVHQHVVDQGSRVVLEOHOHDNV.HHSDOORSHQLQJVIRUFRPEXVWLRQ
and ventilation air clear and unobstructed.
 .HHSWKHHQWLUHSRROKHDWHUDUHDFOHDQDQGIUHHRIDOOGHEULVFRPEXVWLEOHPDWHULDOVJDVROLQHDQGRWKHU
ÀDPPDEOHYDSRUVDQGOLTXLGV5HPRYHDQ\OHDYHVRUSDSHUIURPDURXQGWKHKHDWHU
4. Do not store chlorine, other pool chemicals, or other corrosives in the vicinity of the heater.
5. If the heater is operating on propane gas, the tank must not fall below 30% full or damage to the heater
may occur. Hayward will not be responsible for heaters that soot up due to improper gas level in the
tank resulting in inadequate gas volume.
6. If another appliance is added to the gas line at a later date, consult the local gas company to be sure the
gas line will have the capacity to supply both units at full input rating at the same time.
 'RQRWXVHWKHKHDWHULIDQ\SDUWKDVEHHQXQGHUZDWHU&RQWDFWDTXDOL¿HGVHUYLFHWHFKQLFLDQWRLQVSHFW
the entire heater and replace any part of the control system or gas valve that was under water. If heater
has been totally submerged in water it must be removed and the entire heater must be replaced.
 $QLQVSHFWLRQSURJUDPLVDJRRGSUHYHQWDWLYHPDLQWHQDQFHPHDVXUH.HHSWKLVPDQXDOLQDVDIHSODFH
for future reference for yourself as well as for a service technician to consult when inspecting or servic-
LQJWKHKHDWHU$GGLWLRQDOLQVSHFWLRQSURFHGXUHVWREHSHUIRUPHGE\DTXDOL¿HGVHUYLFHWHFKQLFLDQDUH
covered in 6HFWLRQ9,RIWKLVPDQXDO
VA&+./Ab%+A#&]
In moderate climates, the heater can continue to operate during short-term cold spells. Do not use the
KHDWHUWRPDLQWDLQWKHZDWHUWHPSHUDWXUHMXVWDERYHIUHH]LQJRUIRUIUHH]HSURWHFWLRQ&DUHPXVWEHWDNHQWR
avoid freeze-up in the heater. When it is used during freezing weather, the pump must run continuously. The
heater is not warranted against freeze-ups. In regions where freezing temperatures are encountered, all water
must be drained from the heater when it is out of service, to prevent damage to the heater and piping. Drain-
ing the heat exchanger is recommended as part of the season’s shutdown procedures.
ATTENTION: A heater damaged by freezing is not covered under the Hayward warranty.

Table of Contents

Other manuals for Hayward H150FD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward H150FD and is the answer not in the manual?

Hayward H150FD Specifications

General IconGeneral
BrandHayward
ModelH150FD
CategorySwimming Pool Heater
LanguageEnglish

Related product manuals