Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
.X,A"9.&+!A&(".:+A#&]
On receipt of the heater, inspect the heater carton(s) for damage. If any carton(s) is damaged, note it when
signing for it. Remove the heater from the carton(s) inspect it and advise the carrier of any damages at once.
A9"#/+%&+!&#+A:.]
7KHLQVWDOODWLRQLQVWUXFWLRQVDUHLQWHQGHGIRUWKHXVHRIDTXDOL¿HGWHFKQLFLDQVSHFL¿FDOO\WUDLQHGDQG
experienced in the installation of this type of heating equipment. Some states or provinces require that instal-
lation be licensed. If this is the case in the state or province where heater is located, the contractor must be
properly licensed.
WARNING: Failure to comply with the appliance and vent package installation instructions and service
LQVWUXFWLRQVLQWKLVPDQXDOPD\UHVXOWLQHTXLSPHQWGDPDJH¿UHDVSK\[LDWLRQRUFDUERQPRQR[LGHSRL-
soning. Exposure to products of incomplete combustion (carbon monoxide) can cause cancer and birth
defects or other reproductive harm.
:#&3#/9%&:.!VA+*!:#'.(]
The heater shall be installed in accordance with all local and state codes. The heater installation must con-
IRUPWRWKHODWHVWHGLWLRQRIWKH1DWLRQDO)XHO*DV&RGH$16,=1)3$DQGZLWKWKHUHTXLUHPHQWVRI
WKHDXWKRULW\KDYLQJMXULVGLFWLRQ'HVLJQFHUWL¿FDWLRQRIWKHKHDWHULVLQFRPSOLDQFHZLWK$16,=&6$
)RU&DQDGLDQLQVWDOODWLRQVWKHKHDWHULVWREHLQVWDOOHGLQDFFRUGDQFHZLWKWKHVWDQGDUGV&$1&*$%
DQG%±,QVWDOODWLRQ&RGHVIRU*DV%XUQLQJ$SSOLDQFHVDQG(TXLSPHQWDQGRUORFDOFRGHVDQGLIDSSOL-
FDEOH&6$&±&DQDGLDQ(OHFWULFDO&RGH3DUW,
%$+A+,'.!#3!A&(+%$$%+A#&]
The heater may be installed at any altitude up to 10,100 ft above sea level, provided the appropriate
PRGL¿FDWLRQVDUHSHUIRUPHG7KHDOWLWXGHVZKLFKUHTXLUHPRGL¿FDWLRQYDU\GHSHQGLQJRQWKHPRGHO3DUWV
necessary to convert the heater for outdoor installation at altitudes up to 7,700 ft (minimum) are included
ZLWKWKHKHDWHU&RQYHUVLRQLVDFFRPSOLVKHGE\UHSODFHPHQWRIWKHEORZHUDLULQOHWSODWHDQGIRULQGRRUDS-
plications, installation of a special vent pressure switch. The blower air inlet plates are clearly marked with
WKHFRPSDWLEOHKHDWHUPRGHOVYHQWFRQ¿JXUDWLRQVDQGDOWLWXGHUDQJHV&DUHVKRXOGEHWDNHQWRYHULI\
the correct plate (and vent pressure switch, when applicable) is being used to ensure proper heater perfor-
mance. The vent pressure switch should be provided with the indoor adapter kit, or if you have an older
LQGRRUDGDSWHUNLWRUGHUSQ)';/936IRUWKHKLJKDOWLWXGHLQGRRUYHQWSUHVVXUHVZLWFK
+LJK$OWLWXGH&RQYHUVLRQ3URFHGXUH
,GHQWLI\WKHDOWLWXGHRIWKHLQVWDOODWLRQVLWH7KLVPD\EHGRQHXVLQJD*36GHYLFHRUE\ORRNLQJXSWKH
DOWLWXGHIRUWKHJHRJUDSKLFORFDWLRQ$OWLWXGHVIRUDOOORFDWLRQVLQWKH8QLWHG6WDWHVDQG&DQDGDPD\EH
IRXQGXVLQJWKH]LSSRVWDOFRGHGDWDEDVHDWZZZ]LSFRGHVFRP,IWKHDOWLWXGHIRUWKHLQVWDOODWLRQVLWH
is greater than 10,100 ft, the heater may not be installed. Note that if installing outdoors, some
8QLYHUVDO+6HULHVKHDWHUVPD\EHFRPSDWLEOHZLWK\RXUDOWLWXGHZLWKRXWPRGL¿FDWLRQ7DEOHOLVWVWKH
DOWLWXGHUDQJHVIRUKHDWHUVZLWKRXWPRGL¿FDWLRQ$OOLQGRRUKHDWHUVLQVWDOOHGDERYHIWUHTXLUHD
special vent pressure switch.
6HOHFWWKHDSSURSULDWHEORZHUDLULQOHWSODWHWRXVHEDVHGRQWKHKHDWHUPRGHOYHQWFRQ¿JXUDWLRQ
(outdoor or indoor), and altitude needed. Extra plate(s) are included with the heater, packaged in the
SODVWLFEDJZLWKWKLVPDQXDO(DFKSODWHKDVDODEHOZKLFKLGHQWL¿HVZKLFKPRGHOVYHQW
FRQ¿JXUDWLRQVDQGDOWLWXGHUDQJHVLWLVGHVLJQHGIRU7DEOHOLVWVWKHPD[LPXPLQVWDOODWLRQ
altitudes using the included conversion plate(s). If installing above 7,700 ft, the high-altitude kit
(.:+A#&!AAH!A&(+%$$%+A#&