DS-KH9510-WTE1 Video Intercom Indoor Station Configuration Guide
CG DS-KH9510-WTE1 Video Intercom 031621NA 9
Figure 6, Zone Settings
2. Press a zone to pop up the zone editing dialogue box.
3. Set the zone type, alarm type, status of arming status, entering delay, and exiting delay.
4. Tap OK to save the settings.
• Seven zone types are selectable: Panic Button, Door Magnetic, Smoke Detector, Active Infrared,
Passive Infrared, Gas Detector, and Doorbell.
• Three alarm types are selectable: 24h Alarm, Instant Alarm, and Delay Alarm. Set the alarm type
as 24h alarm, and the zone will be armed for 24h.
- Set the alarm type as instant alarm, and the zone will alarm once it's triggered.
- Set the alarm type as delay alarm, and you should set the entering delay duration and exiting
delay duration.
• Both the entering delay duration and the exiting delay duration are from 30s to 60s.
• For Gas Detector and Smoke Detector, the alarm type is set as default 24h alarm. The alarm type
of them can not be changed.
Arming Mode Settings
Four arming modes can be configured: stay mode, away mode, sleeping mode, and custom mode.
Before You Start
Tap Settings → → Shortcut Settings to enable Zone Alarm Locally.
Steps
Arming status page and zone settings page are hidden by default. You should enable alarm function first.
1. Tap Settings → → Scene Settings to enter the arming mode settings page.
2. Tap Stay Mode, Away Mode, Sleeping Mode, or Custom to enter the page.