DS-KH9510-WTE1 Video Intercom Indoor Station Configuration Guide
CG DS-KH9510-WTE1 Video Intercom 031621NA 21
Figure 19, RS-485 Settings
NOTE: For indoor station and master station, there are three choices for the working mode:
transparent channel, disable, and custom.
2.4.2 Video Intercom
Click Video Intercom on the remote configuration page to enter the video intercom parameters settings:
Device Number Configuration, Time Parameters, Password, Zone Configuration, IP Camera Information,
Volume Input and Output Configuration, etc.
Time Parameters
Steps
1. Click Time Parameters to enter time parameters settings page.
Figure 20, Time Parameters
2. Configure the maximum ring duration, maximum live view time, and call forwarding time.
3. Click Save.
NOTE: Maximum ring duration is the maximum duration of indoor station when it is called without
being received. The range of maximum ring duration varies from 30s to 60s.
Maximum live view time is the maximum time of playing live view of the indoor station. The
range of maximum live view time varies from 10s to 60s.
Call forwarding time refers to the ring duration limit beyond which the call is automatically
forwarded to the mobile phone designated by the resident. The range of call forwarding
time varies from 0s to 20s.
For indoor extension, it only requires setting the maximum live view time.