7-73
M4GB-07-087
M4GB-07-088
M4GB-07-088
Push down open/close lever (1) inside the engine compart
-
ment. Side cover (2) at the radiator can be opened.
Check and clean engine intercooler (3), air condenser (4),
and torque converter oil cooler (5). Locations of catch le
-
ver (6) and other cooling equipment differ depending on
machine models. When torque converter oil cooler (5) is
dislocated by pushing down catch lever (6), clearance (10) in
front of the radiator can be cleaned.
Check and clean radiator (7), hydraulic oil cooler (8), and hy
-
draulic driven fan (9).
In case dirt or dust has adhered to the radiator/oil cooler
cores, clean the radiator/oil cooler cores with compressed
air pressure [less than 0.2 MPa (2 kgf/cm
2
)] or tap water to
prevent the cooling system performance from being re-
duced.
Operating the fan reverse rotation switch on the right con
-
sole can conduct brief cleaning. Keep any personnel away
from the vicinity.
6