7-77

 











 
 
 

 
 

 
 

 



 
 

 
 


Check the electrolyte specific gravity in each battery
cell.
The lowest limit of the specific gravity for the elec
-
trolyte varies depending on electrolyte temperature.
The specific gravity should be kept within the range
shown below. Charge the battery if the specific grav-
ity is below the limit.

Your machine has two 12-volt batteries with negative (−)
ground.
If one battery in a 24-volt system has failed but the other is still
good, replace the failed battery with one of the same type. For
example, replace a failed maintenance-free battery with a new
maintenance-free battery. Different types of batteries may
have different rates of charge. This difference could overload
one of the batteries and cause it to fail.
Recommended range of specific gravity by electrolyte temperature
Working Range
40°C
(104°F)
1.21 1.22 1.23 1.24 1.25 1.26 1.27 1.28 1.29 1.30 1.31 1.32
Specific gravity of battery fluid
Fluid temp.
20°C
(68°F)
0°C
(32°F)
–20°C
(–4°F)
–40°C
(–40°F)