EasyManuals Logo
Home>Hitron>Modem>E31N2V1

Hitron E31N2V1 User Manual

Hitron E31N2V1
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Version 1.0, 11/2017. Copyright 2012 Hitron Technologies
33
Version 1.0, 11/2017. Copyright 2017 Hitron Technologies
33
Hitron E31N2V1 Users Guide
1.5 The Status: DOCSIS Event Screen
Use this screen to view information about local WAN activity events.
Click Status > DOCSIS Event. The following screen displays.
BW (sc’s*fft) This displays the bandwidth of the relevant channel,
expressed as the number of subchannels multiplied by
the channel’s Fast Fourier Transform size, in megahertz
(MHz).
Report Power This displays the reported power of the relevant
channel, in quarter-decibels above/below 1 millivolt
(quarter-dBmV).
Report Power 1_6 This displays the target power (P1.6r_n, or power
spectral density in 1.6MHz) of the relevant channel, in
quarter-decibels above/below 1 millivolt (quarter-
dBmV).
FFT Size This displays the type of Fast Fourier Transform in use
on the relevant channel.
Table 5: The Status: DOCSIS WAN Screen (continued)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitron E31N2V1 and is the answer not in the manual?

Hitron E31N2V1 Specifications

General IconGeneral
BrandHitron
ModelE31N2V1
CategoryModem
LanguageEnglish

Related product manuals