OPERATION
53
AC OPERATION
If an appliance begins to operate abnormally, becomes sluggish, or stops
suddenly, turn it off immediately. Disconnect the appliance, and determine
whether the problem is in the appliance or the rated load capacity of the
generator has been exceeded.
Substantial overloading may damage the generator. Marginal overloading may
shorten the service life of the generator.
1. Turn the voltage selector switch to either position.
With the voltage selector switch in the “120V/240V” position, you can use the
120V and 120V/240V receptacles simultaneously. If you are NOT using 240
volts, then select the “120V ONLY” position.
Disconnect or turn OFF all appliances or tools connected to the generator before
changing the voltage selector switch position.
The generator may be damaged if the switch position is changed with loads
connected and operating.
2. Start the engine (see page 44).
VOLTAGE SELECTOR SWITCH
120 V/240 V
120 V ONLY