27
CONTROLS & FEATURES
i-Monitor Low Battery Message
If the ENGINE START button is pressed and ‘‘batt’’ is blinked on the
i-Monitor display, the battery voltage is too low to operate the engine’s
electric starter. Use the recoil starter to start the generator. Have the
battery recharged and checked (see page
65).
i-Monitor System Error Messages
If the generator has a system malfunction, it will blink an error message
on the i-Monitor display. During remote control operation, an E-01 error
message may display if the ENGINE START button is pressed for more
than 10 seconds. With an E-01 error message, the engine will stay
running and the electrical output may stay constant.
Normal remote control operation will be restored after the E-01 error
message clears automatically. If the E-01 error message does not clear
automatically or if any other error message displays, contact your
servicing dealer.
“batt” blinks
OIL ALERT/CHECK INDICATOR
ERROR MESSAGE
(Example: E-01)
“E-01” blinks
36Z376000.book 27 ージ 014年9月19日 金曜日 午後6時26分

Table of Contents

Other manuals for Honda EU70is

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honda EU70is and is the answer not in the manual?

Honda EU70is Specifications

General IconGeneral
ModelEU70is
TypeInverter
Maximum AC Output7000 VA
Rated AC Output5500 VA
EngineGX390
Engine Displacement389 cc
Fuel TypeGasoline
Run Time per Tankful6.5 hours at rated load
Starter SystemElectric
DC Output12V, 8.3A
Run Time at 1/4 Load18 hours
Noise Level52 dB(A) at 1/4 load
Rated Voltage220-240V