65
SERVICING YOUR GENERATOR
Battery Charging
The battery is rated at 11.2 Ah (ampere-hours). Charging current
should equal 10% of the battery’s ampere-hour rating. A battery
charger should be used that can be adjusted to deliver 1.1 amps.
1.Connect the battery charger following the manufacturer’s
instructions.
2.Charge the battery 5–10 hours.
3.Clean the outside of the battery and the battery compartment with a
solution of baking soda and water.
Battery Installation
1.Install the battery into the generator.
2.Connect the positive (+) cable to the battery positive (+)
terminal first, and tighten the bolt securely.
3.Slide the battery boot over the positive (+) cable and terminal.
4.Connect the negative (–) cable to the battery negative (–)
terminal, and tighten the bolt securely.
5.Install the battery strap.
6.Install the battery maintenance cover in the reverse order of removal
(see page 63).
Never operate the generator with the battery maintenance cover
open, as poor engine and generator performance will result.
The battery gives off explosive
hydrogen gas during normal
operation.
A spark or flame can cause the
battery to explode with enough
force to kill or seriously hurt you.
Wear protective clothing and a face
shield, or have a skilled mechanic
perform the battery maintenance.
36Z376000.book 65 ージ 014年9月19日 金曜日 午後6時26分

Table of Contents

Other manuals for Honda EU70is

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honda EU70is and is the answer not in the manual?

Honda EU70is Specifications

General IconGeneral
ModelEU70is
TypeInverter
Maximum AC Output7000 VA
Rated AC Output5500 VA
EngineGX390
Engine Displacement389 cc
Fuel TypeGasoline
Run Time per Tankful6.5 hours at rated load
Starter SystemElectric
DC Output12V, 8.3A
Run Time at 1/4 Load18 hours
Noise Level52 dB(A) at 1/4 load
Rated Voltage220-240V