EasyManuals Logo
Home>Honeywell>Barcode Reader>5010

Honeywell 5010 User Manual

Honeywell 5010
199 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
3 - 5
TTL Level 232 Interface
The 5X80 provides a TTL level serial 232 communication link. TTL Level 232
Inverted is the “normal” mode that allows direct communication from the 5X80 to
a standard PC RS-232 serial port with the use of cable (part number 42206139-
04).
Non-Inverted serial TTL communication is provided to allow direct connection to
a TTL UART port, or to an RS-232 driver integrated circuit. Note that if theTTL
Level 232 Non-Inverted bar code is scanned, the 5X80 will no longer
communicate with a standard PC RS-232 port.
TTL Level 232 Inverted with Polarity Override allows direct communication from
the 5X80 to a standard PC RS-232 serial port with the use of cable (part number
42206139-04). This setting also allows you to override the polarity externally.
Note: For further information on the TTL Level 232 Interface, refer to the 5X10/
80 Integration Manual.
RTS/CTS On
* XON/OFF Off
* RTS/CTS Off
XON/XOFF On
ACK/NAK On
* ACK/NAK Off