16 Mass Notification — P/N LS10063-000NF-E:E 06/26/2019
Programming Programming Steps
3.2.2 LOC
An LOC is comprised of a DVC in LOC mode, (with an NCA-2 or NFS2-3030 in network display mode) or a DVC-RPU combined with
an LCD-160. The LCD-160 must be associated with the NCA-2 or NFS2-3030 (in network display mode) that is being used for the
ACU. The DVC-RPU must be associated with the DVC used for the ACU.
3.2.3 CCS
A CCS is comprised of an NFS2-3030 and a DVC, or an NCA-2 and a DVC, or an ONYXWorks Workstation.
LOC Programming Steps
DVC
Field Refer to:
1 Set the MN mode, enable paging levels. page 21
2 Enter associated NFS2-3030*/NCA-2 node number. page 19
3 Program input categories and priorities page 21, page 22
4 Create and program an MN Active Tone page 25
5 Create and program a Fire Active Tone (when Fire is the highest priority). page 29
DVC-RPU
1 Enable Paging Levels for which All Call functionality is required. page 33
2 Program the DAL address - critical to LOC operation page 33
LCD-160
1 Program RDP address - critical to LOC operation. page 33
NFS2-3030*/NCA-2
1 Set the MN Control Field to LOC. page 35
* NFS2-3030 must be in network display mode to function as part of an LOC.
CCS Programming Steps
NFS2-3030*/NCA-2
Field Refer to:
1 Set the mass notification priority. page 19
2 Set the DCC field. page 18
3 Set the MN Control Field to CCS. page 35
4 Map to MN nodes. page 23, page 23
5 Program with MN type IDs. page 24
6 Program with MN Special Function Zones. page 25
* NFS2-3030 must be in network display mode to function as part of a CCS.
DVC
1 Set the MN mode, enable paging levels. page 21
2 Enter associated NFS2-3030/NCA-2 node number. page 19
3 Program input categories and priorities. page 21, page 22
4 Create and program an MN Active Tone. page 25
5 Create and program a Fire Active Tone (when Fire is the highest priority). page 29
ONYXWorks Workstation
1 Set the workstation to FCC Mode. manual
2 Set the DCC field to disabled manual
3 Configure the Notify-IP feature. manual