HOW
TO USE THE ARB MODE
7
Trigger on
the
rising edge.
5
o
@
Z
AXIS
INPUT
@
(blue
shift)
Redefines the
3314A
l!IS an ARBitrary
Waveform
Generator (the
shifted
function
etso
ARB clears
the
currant
waveform
to
its initial
state]
. An ARB
waveform
consists
of
a
series
of
voltage ramps called
vectors
.
2
3
4
V HGT
V LEN
INS
Use
the
Modify
knob
to
change the
Vector
Haight
of the
current
vector
.
The
last
vector
closes the
waveform.
Its
length Is progremmable
bot
not
Its he
ight
.
Use
the
Modify
knob
to
chanqe the
vector
length of the
current
vector.
Note
that
the slope does not change and
that
the
waveform
may
clip at
the
peak-to-peak
Um
lt
sot
with
the AMPTD para
mater
when
V LEN Is
very
large.
Each
time
this
key
is pressed, anothel'
vector
is in
sert
ed Into
the
wavafonn
.
Repeat
steps
2
through
4
to
build an ARB
waveform
. The
intensified
portfoo
of
the
oscilloscope display Is
the
current
vector
.
6
6
7
B
V MKR
DEL
At
FREQ
Use
the
Modify
knob
to
change tho
current
vector
. Note
that
the
Intensified
vector
on
the
oscilloscope
trecks
V MKR.
Eech
time
this
key
I
II
pressed. the
current
vector
ill
removed
from
the ARB
waveform
. The
last
vector
cannot
be
removed.
Thla
parameter
changes the period of
the
unit
vector
(V LEN X% 1). Use
the
Modify
knob
to
change this parameter.
Use
the
Modify
knob
to
change the
repetition
frequency of the
entire
ARB
waveform.
Note
the
3314A
aetusUy
computes
a
new
A t.
ARB
Mode Summary
The
3314A
has s
lx
ARB
waveforms
(accessed by RCL ARB 0
to
5).
There are 8
maximum
of
160
vectors
distributed
among these 6
wllveforms
(2
vectors
per
waveform
.
m
inimum
I. The In
iti
alized ARB
waveform
(also
the
minimum
waveform)
is a 2
vector
waveform
with
V HGT
~
000.
V LEN = 1, V MKR - 1 end A t = .200ms.
V
HGHT
range : -19 99 to + 1
999
V LEN range : 1
to
127
A t range: .200ms to
19.99ms
Phase range :
-90
0
to +
90
0
(sets
the
waveform
closure
between
the peak-to-peak
limits
set by AMPTD).
AMPTD
sets
the
peak
-to-peek
limits
that
the ARB
weve
form
must
exist
w
ith
in.
See
Waveforms
51
through
60
In the
Waveform
Ubrary
.
19

Table of Contents

Other manuals for HP 3314A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 3314A and is the answer not in the manual?

HP 3314A Specifications

General IconGeneral
BrandHP
Model3314A
CategoryPortable Generator
LanguageEnglish

Related product manuals