EasyManuals Logo
Home>HP>Inverter>8642A

HP 8642A Operation And Calibration Manual

HP 8642A
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #169 background imageLoading...
Page #169 background image
Model
8642A/B
Operation
Modulation
Oscillator
(cont'd)
Related
Special
Functions
Special
Function
213.
When
modulation
frequency
correction
is disabled,
the
Signal
Generator
does
not
automatically
recalibrate
at
each
modulation
frequency
when
one
is
selected. Instead,
the
instrument
uses, as its
calibration
data,
the
previously
calculated
calibration
factor
for
each
frequency
band.
The
accuracy
of
previously
calculated
calibration
factors
depends on
variations
in
temperature
from
the
time
the
calibration
factor
was selected. Typically,
2%
accuracy
can
be
degraded
to
5%
if
recalibration
is
not
performed
when
the
Signal
Generator
is
subjected
to
temperature
changes
of
SO°C.
DC
FM
Update
Mode (Special
Function
117) also increases
modulation
frequency
switching
by
up to
200
ms.
(Refer
to Special
Function
117
description
in
Modulation,
FM
on
page
3-116).
Spurious
Signals
(Spurs)
That
Occur
with
the
Internal
Source
Internally
generated
spurs
(with
levels specified less
than
-100
dBc)
might
be present
when
the
internal
modulation
oscillator
is
in
usc. These spurs will be
eliminated
when
no
internal
modulation
source
is
modulating
the
carrier,
and
the
modulation
oscillator
output
(MOD OUT)
is
off.
Modulation
Output
Phase
The
phase
of
the
modulation
output
(MOD OUTPUT)
is
180
0
out-of
-phase
with
the
internal
use
of
the
modulation
oscillator.
Underranging
Specified
Modulation
Oscillator
Frequency
Modulation
oscillator
frequencies
as low as
10Hz
can
be selected. However,
the
modulation
oscillator's signal
characteristics
are
not
specified below
20
Hz.
113.
Modu
la
tion
Frequency
Correction
Off.
This
special
function
disables
the
single-band
calibration
of
the
modulation
frequency
oscillator
that
normally
occurs
whenever
the
modulation
oscillator
frequency
is
set or
the
internal
modulation
oscillator
is
put
into
use
When
this
calibration
is
disabled,
the
typical
modulation
frequency
switching
time
is
decreased
by
approximately
200
ms.
For
more
information,
refer
"Speeding Up
Modulation
Switching
Time" on page
3-132.
213.
Modulation
Frequency
Correction
On.
This
special
function
re-enables
the
modulation
frequency
correction
disabled
with
Special
Function
113.
248.
Calibrate
the
Modulation
Frequency
Bands
Again.
This special
function
enables
you to
initiate
the
calibration
sequence
that
normally
only
occurs
during
instrument
power-up.
This
function
can
be
used,
for
example, to
recalibrate
the
modulation
oscillator
frequency
bands
if
normal
modulation
frequency
correction
has
been
disabled
with
Special
Function
113.
Calibration
typically
takes
one
to
two
seconds.
3-133

Table of Contents

Other manuals for HP 8642A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 8642A and is the answer not in the manual?

HP 8642A Specifications

General IconGeneral
BrandHP
Model8642A
CategoryInverter
LanguageEnglish

Related product manuals