EasyManuals Logo
Home>HP>Server>AlphaServer ES80

HP AlphaServer ES80 User Manual

HP AlphaServer ES80
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #144 background imageLoading...
Page #144 background image
AlphaServer ES47/ES80/GS1280 Server Management CLI Reference
2. Run test 13 on all CPUs in the hard partition Default_HP
MBM> test 13
Running test 13, RAID channel Test ... on 2 EV7s
[2003/04/18 15:22:38]
~DIA-W-(pco_04) Test 13 [RAID channel Test] failed on cpu [NS: 0 EW: 0] which i0
[2003/04/18 15:22:38]
BEGIN DIAGNOSTIC TEST FAILURE INFO BEGIN
Test target cabinet:00 drawer:0 CPU0
test number: 13 (hex) [RAID channel Test]
test status: 03
rsvd1: 00
result length: 003e
revision: T1.0-9_ocla
error number: 01 -- Write, Verify Read error
rsvd2: 00
error format: 01
severity code: 01
FRU1: 0
FRU2: 0
FRU3: 0
FRU4: 0
P1: ffff8000.00000000 Expected data (written)
P2: 00000000.00000000 Actual data received (read)
P3: ffff8000.00000000 Failing Address
P4: 00000000.00000000 (null)
P5: 00000000.00000000 (null)
P6: 00000000.00000000 (null)
P7: 00000000.00000000 (null)
P8: 00000000.00000000 (null)
FRU suspect: EV7, Memory
FRU extra: Ev7 not capable of RAID cab:00 drw:0 CPU0
END DIAGNOSTIC TEST FAILURE INFO END
MBM>
See Also
power on, reset, enable test, disable test
3-120

Table of Contents

Other manuals for HP AlphaServer ES80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP AlphaServer ES80 and is the answer not in the manual?

HP AlphaServer ES80 Specifications

General IconGeneral
BrandHP
ModelAlphaServer ES80
CategoryServer
LanguageEnglish

Related product manuals