AlphaServer ES47/ES80/GS1280 Server Management CLI Reference
3.45 set init
Sets the initialization string that is sent to the modem when the enable remote command is
issued. The initialization string is stored in the MBM’s EEPROM and has a maximum length of 31
characters.
Because modem commands disallow mixed cases, all alphabetic characters entered in the init
string are converted to uppercase. It also automatically configures the modem’s flow control
according to the flow control setting and enables the modem carrier detect features to monitor the
modem connectivity.
Syntax
set init
[<init_string>]
Argument
init_string The ASCII string that is sent to the modem when the system management
CLI attempts to initialize it for remote access and sending of alerts. The
init string is erased if no parameter is given.
Options
None
Example
Set up the initialization string.
MBM> set init ate0v0&c1s0=3
MBM>
See Also
enable remote, show modem