AlphaServer ES47/ES80/GS1280 Server Management CLI Reference
3.71 test led
Tests all IP and IO cable port LEDs. This command turns the cable LEDs on or off. Setting it for 0
seconds turns the LEDs off. The default is to blink the LEDs for 60 seconds. The maximum is
3600 seconds.
Syntax
test led
[<seconds>]
Argument
seconds The amount of time to leave the cable LEDs on or to turn
them off.
Options
None
Examples
1. Blink the cable LEDs for the default amount of time (60 seconds).
MBM> test led
MBM>
2. Turn off the cable LEDs.
MBM> test led 0
MBM>
See Also
config cables