For detailed instructions, see the service advisory on the HPE website:
https://www.hpe.com/support/apollo2000gen10plus-reentering-SN-PID
c. Reboot the server.
Removing and replacing the RCM sideband cable
Prerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
Procedure
1. Power down the servers.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the chassis.
3.
If installed,
disconnect the tube set.
4.
Disconnect all peripheral cables from the servers and chassis.
5.
Remove the chassis from the rack.
6.
Remove the access panel.
7.
Remove the PDB cover screws (callout 1), and then remove the cover (callout 2).
8. Disconnect the RCM sideband cable from the PDB and the RCM board.
To replace the component, reverse the removal procedure.
Removal and replacement procedures
65