Specifications
Environmental specifications
Specification Value
Temperature range
1
—
Operating 10°C to 35°C (50°F to 95°F)
Nonoperating –30°C to 60°C (–22°F to 140°F)
Relative humidity (noncondensing)
—
Operating 8% to 90%
28°C (824°F), maximum wet bulb temperature
Nonoperating
5% to 95%
387°C (1017°F), maximum wet bulb temperature
1
All temperature ratings shown are for sea level. An altitude derating of 10°C per 305 m (18°F per 1000 ft) to 3050 m (10000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change
might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended. The extended
range is 5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level. An altitude derating of 10°C per every
175 m (18°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m (10000 ft) is applicable.
Mechanical specifications
Apollo n2600 Gen10 Plus Chassis
Specifications
Value
Dimensions
—
Height 8750 mm (344 in)
Depth 92400 mm (3638 in)
Width 44000 mm (1732 in)
Weight (approximate maximum values)
—
Empty chassis (chassis without the drives, power supplies, RCM
module, server nodes, and server blanks)
1317 kg (2903 lb)
8 SFF drive configuration 4018 kg (8858 lb)
24 SFF drive configuration 4673 kg (10302 lb)
Specifications 95