Table 5 HP P10000 3PAR Storage System Power Requirements per Cabinet (continued)
200200Drive Chassis (no magazines)
Drive Magazine
3
4 x 100 GB SSD Drive Magazine
5.59.8Watts
1933BTUs/hour
4 x 200 GB SSD Drive Magazine
710.3Watts
2435BTUs/hour
4 x 300 GB FC Drive Magazine
5775Watts
195256BTUs/hour
4 x 600 GB FC Drive Magazine
6576Watts
222258BTUs/hour
4 x 2 TB NL Drive Magazine
3862Watts
131211BTUs/hour
Service Processor
317Watts
1,082 BTUs/hr.BTUs/hour (fully populated)
1 Theoretical maximum based on branch circuit capacity.
2 Under maximum load.
3 Up to 10 drive magazines (40 drives) per drive chassis.
NOTE: Refer to “Power Requirements” (page 29) for complete details.
Environmental Specifications
The following table lists the environmental specifications for the HP P10000 3PAR Storage Systems.
Table 6 Environmental Specifications for the HP P10000 3PAR Storage System
ValueSpecification
0 –10,000 ft (3,048 m) 0 –40,000 ft (12,192 m)Altitude Operating Nonoperating
50 –104° F (10–40° C) 0–3,000 ft (914.4 m) 50 –9 F
(10 –3 C) 3,000–10,000 ft (914–3,048 m) –40 –20
F (–40– 9 C) 0–40,000 ft (0–12,192 m)
Ambient temperature Operating Nonoperating
1 F/hr (1 C/hr) 1 F/hr (1 C/hr)Temperature gradient Operating Nonoperating
20 80 percent noncondensing, maximum gradient 10
percent per hour
Relative humidity
12 System Components and Specifications

Table of Contents

Other manuals for HP P10000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP P10000 and is the answer not in the manual?

HP P10000 Specifications

General IconGeneral
BrandHP
ModelP10000
CategoryStorage
LanguageEnglish

Related product manuals