Table 5 HP P10000 3PAR Storage System Power Requirements per Cabinet (continued)
200200Drive Chassis (no magazines)
Drive Magazine
3
4 x 100 GB SSD Drive Magazine
5.59.8Watts
1933BTUs/hour
4 x 200 GB SSD Drive Magazine
710.3Watts
2435BTUs/hour
4 x 300 GB FC Drive Magazine
5775Watts
195256BTUs/hour
4 x 600 GB FC Drive Magazine
6576Watts
222258BTUs/hour
4 x 2 TB NL Drive Magazine
3862Watts
131211BTUs/hour
Service Processor
317Watts
1,082 BTUs/hr.BTUs/hour (fully populated)
1 Theoretical maximum based on branch circuit capacity.
2 Under maximum load.
3 Up to 10 drive magazines (40 drives) per drive chassis.
NOTE: Refer to “Power Requirements” (page 29) for complete details.
Environmental Specifications
The following table lists the environmental specifications for the HP P10000 3PAR Storage Systems.
Table 6 Environmental Specifications for the HP P10000 3PAR Storage System
ValueSpecification
0 –10,000 ft (3,048 m) 0 –40,000 ft (12,192 m)Altitude Operating Nonoperating
50 –104° F (10–40° C) 0–3,000 ft (914.4 m) 50 –95° F
(10 –35° C) 3,000–10,000 ft (914–3,048 m) –40 –203°
F (–40– 95° C) 0–40,000 ft (0–12,192 m)
Ambient temperature Operating Nonoperating
18° F/hr (10° C/hr) 18° F/hr (10° C/hr)Temperature gradient Operating Nonoperating
20 – 80 percent noncondensing, maximum gradient 10
percent per hour
Relative humidity
12 System Components and Specifications