EasyManuals Logo
Home>HP>Adapter>XP

HP XP User Manual

HP XP
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
Explanation
Pair resynchronization of P-VOL and S-VOL failed.
Recommended action
An error occurred when an operation command was given to a disk array system.
See “About errors attributable to disk array systems” (page 133).
5014
Type
Error
Message
Failed to restore Business Copy pair: S-VOL [LU number of S-VOL] --> P-VOL [LU number of
P-VOL], Error# [Error number]
Explanation
Restore from S-VOL to P-VOL failed.
Recommended action
An error occurred when an operation command was given to a disk array system.
See “About errors attributable to disk array systems” (page 133).
5017
Type
Error
Message
Failed to create V-VOL for P-VOL [LU number of P-VOL], Error# [Error number] You must use
a RAID level with redundancy for both the P-VOL and data pool as RAID 0 is not supported
Explanation
Cannot create V-VOL for P-VOL. RAID0 is not supported.
Recommended action
P-VOL of Snapshot became a RAID0 LU. Specify an LU that is not RAID0.
5019
Type
Error
Message
Failed to resync the shadow copy: Serial Number: [ serial number] Source Lun[LU number]
-->Target Luns[LU number], Error# [Error number]
Explanation
Resynchronization processing failed.
Error messages 77