Provides an access security mechanism, assigns rights to users based on roles,
and implements IP address control over HTTPS, SNMPv3, and SNMP access to
prevent unauthorized access.
Provides comprehensive UPS management, such as producing a current
diagram, displaying alarms, controlling UPS running, collecting performance
data statistics, as well as allowing users to view, retrieve, and export historical
alarms and operation logs.
Supports optional components such as temperature and humidity modules,
AI/DI Module, and external dry contact card.
Works with NetShutdown, a computer and server security shutdown program
developed by Huawei, to automatically shut down the computers and servers
where NetShutdown is installed to protect customer data and reduce loss.
Works with RCCMD, a client shutdown software developed by Generex, to
automatically and safely shut down the client that is installed with the
RCCMD, thereby protecting customers' data and preventing loss.
Sends alarm information to a
specied email address (for example, 163 email
address) at scheduled time.
6.3 Modbus Card
The RMS-MODBUS01A provides an RS485 networking solution to remotely
manage the UPS.
The card implements the following functions by setting the DIP switches:
Provides a DIP switch for selecting the RS485 communications protocol. The
Modbus and YDN-23 protocols are supported.
Uses a DIP switch to select a two-wire or four-wire system.
Provides a DIP switch to select a build-out resistor.
Provides a DIP switch for setting the optional card address.
Supports hot swap.
6.4 Dry Contact Card
The RMS-RELAY01A is installed in an optional card slot and supports hot swap.
The dry contact card provides six alarm dry contact outputs (normal mode, battery
mode, bypass mode, low battery voltage, bypass backfeed, and UPS faults) and
two dry contract control inputs (one is the shutdown signal input, and the other is
reserved).
UPS2000-G- (6 kVA-20 kVA)
User Manual 6 Communications
Issue 18 (2021-07-16) Copyright © Huawei Technologies Co., Ltd. 102

Table of Contents

Other manuals for Huawei UPS2000-G-10KRTL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei UPS2000-G-10KRTL and is the answer not in the manual?

Huawei UPS2000-G-10KRTL Specifications

General IconGeneral
BrandHuawei
ModelUPS2000-G-10KRTL
CategoryUPS
LanguageEnglish

Related product manuals