OPERATION
HPR400XD Manual Gas Instruction Manual 4-57
Aluminum
H35 Plasma / N
2
Shield
400 A
Flow rates – lpm/scfh
H35 N
2
Preflow 0 / 0 189 / 400
Cutflow 86 / 182 123 / 260
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
mm
Volts mm mm/m mm Factor % Seconds
H35
N
2
40 80 86 80
20
170
9.0
2420 13.5 150 0.7
25
175 1820
18.9 210
1.0
30
177 1590 1.5
40
180 1190 2.0
50
188 790
Edge start
60
200 450
70
208 310
80
210 210
Metric
Marking
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma Shield Plasma Shield Plasma Shield
in
Volts in ipm in Factor % Seconds
H35
N
2
40 80 86 80
3/4
170
0.35
100 0.53 150 0.7
1
175 70
0.74 210
1.0
1-1/4
177 60 1.5
1-1/2
180 50 2.0
1-3/4
184 40
Edge start
2
188 30
2-1/4
200 20
2-1/2
208 15
3
210 10
English
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm in mm/min ipm Volts
N
2
N
2
10 10 10 10
22
2.5 0.10 1270 50 94
ArAir30103010
24
3.0 0.12 2540 100 50
220707220637 220709220712 220405220708 220571